Building Management System
End-to-end monitoring and control for all building systems including HVAC, lighting, elevators, fire safety, and water management.
One unified view of every building system, so operations teams act faster with fewer surprises.
BMS brings HVAC, lighting, elevators, fire safety and water management into one unified view, with digital twin visualization over real-time point data.
Environmental monitoring is CFD-based and extended by gas detection (GDS) and water leak detection (WLDS), so high-density data center conditions stay observable zone by zone.
8 Subsystems Inside BMS
Digital Twin Overview
3D visualization of building systems with real-time data overlay.
Liquid Cooling
Advanced cooling system monitoring for high-density data centers.
Fire Safety
Integrated fire detection and suppression system management.
Water Supply & Drainage
Monitoring of water systems with leak detection.
Elevator Management
Real-time elevator status and predictive maintenance.
Temperature & Humidity
CFD-based environmental monitoring and optimization.
GDS
Gas Detection System monitoring refrigerant, combustible and toxic gas with threshold alarms.
WLDS
Water Leak Detection System with zone-level sensing and instant alarm localization.
BMS Technical Parameters
Platform Baseline
Every system runs on the IntelliOne platform base, so platform-level redundancy supports all five systems and their shared modules uniformly.
Values marked as design standard are engineering targets; 350 MW+ operating load reflects successfully delivered projects.
Redundancy Design in BMS
System-Level Redundancy
Multi-gateway acquisition redundancy with automatic failover to a backup link, keeping building monitoring free of blind spots.
Multi-Gateway Acquisition Redundancy
Field data is collected through multiple gateways; when one gateway fails, acquisition switches automatically to the backup link.
Monitoring Without Blind Spots
All building equipment scenarios stay under observation, so a single gateway fault does not create monitoring blind spots.
Isolated Fault Domain
A fault inside this system is contained by its own redundancy design and does not spread to other modules running on the platform.
Building monitoring without blind spots
Each system is independently highly available: a single system fault is isolated and does not spread to other modules.
Platform Base Support
Level 1 · IntelliOne unified platform layer
Every system runs on the IntelliOne platform base, so platform-level redundancy supports all five systems and their shared modules uniformly. Dual-node hot-standby cluster, multi-copy data storage and dual communication links remove platform-level single points of failure, keeping the global management view continuously available.
Deployment-Level Redundancy
Level 3 · Engineering delivery standard
Hardware-Level Redundancy
All control hardware, gateways and core servers use industrial dual-power redundant configuration, so a single supply failure does not affect device operation.
Network-Level Redundancy
Dual physical network links are deployed, with management and control networks physically separated and each carrying its own redundant paths.
Power-Level Redundancy
Critical control nodes include UPS backup as standard, so monitoring, emergency control and data reporting continue during a power loss.
Standard delivery configuration on every project — not an optional add-on. No single point of failure on site, suited to complex grid and environmental conditions across Southeast Asia.
Other Systems & Modules on IntelliOne
See BMS in the Live Console
Explore monitoring, alarms and optimization flows with real-time console access.