Skip to main content
Back to Systems
DCIM system icon
DCIM

Data Center Infrastructure Management

Operational Efficiency

The IntelliOne unified platform carrying BMS, EPMS, CCCS, Common and AI modules on one point database and one alarm center.

One platform from planning and construction through to 24/7 operation, so every site runs the same way.

5
Modules Carried
54W
Points Mapped
Dual-Node
Cluster Deployment
Full Lifecycle
Delivery Coverage
System Overview

The IntelliOne DCIM platform integrates digital twin visualization, tri-agent AI and industrial-grade redundant hot-standby architecture, providing full lifecycle capabilities for intelligent computing centers — from planning and construction to operation.

BMS, EPMS, CCCS, Common and AI modules share one point database and one alarm center, so every site is monitored, controlled and reported in the same way.

Subsystems

4 Subsystems Inside DCIM

Unified Console

Single console for monitoring, alarms, trends and reports across every site.

150msRefresh
Multi-SiteCoverage

Unified Point Database

One point database shared by BMS, EPMS and CCCS, with automated consistency checking.

54WPoints Mapped
99.9%Consistency

Redundant Hot-Standby

Industrial-grade redundant hot-standby architecture for continuous operation.

24/7Operation
187msControl Loop

Full Lifecycle Delivery

Planning, construction, commissioning and operation kept on the same platform.

Full LifecycleCoverage
CXDocumentation
Technical Parameters

DCIM Technical Parameters

Modules Carried
5
BMS · EPMS · CCCS · Common · AI
Points Mapped
54W
One unified point database
Cluster Deployment
Dual-Node
Primary/standby hot-standby
Delivery Coverage
Full Lifecycle
Planning → construction → operation
Data Copies
Multi-Copy
Configuration · runtime · history
Communication Links
Dual
Dual-protocol parallel acquisition

Platform Baseline

Every system runs on the IntelliOne platform base, so platform-level redundancy supports all five systems and their shared modules uniformly.

150ms
Data Refresh
Unified platform specification
187ms
Control Loop
Closed-loop control response
54W
Point Capacity
Largest Single-Site Deployment
99.9%
Data Consistency
Automated validation
99.9%
Platform Availability
Redundant hot-standby cluster
24/7
Operation
Mission-critical coverage

Values marked as design standard are engineering targets; 350 MW+ operating load reflects successfully delivered projects.

Technical Advantages

Redundancy Design in DCIM

Platform-Level Redundancy

Dual-node hot-standby cluster with multi-copy data storage and dual communication links, keeping the platform continuously available.

Dual-Node Hot-Standby Cluster

The core platform runs as a primary/standby server cluster. On primary node failure the switch is automatic and seamless, so monitoring and control continue without manual intervention.

Multi-Copy Data Redundancy

System configuration, real-time runtime and historical O&M data are stored in multiple copies. Single-point data corruption does not affect operation, and recovery and trace-back stay fast.

Communication Link Redundancy

Dual network links with dual-protocol parallel acquisition. When one link is interrupted the backup link takes over automatically, keeping data acquisition and control commands stable.

Core Reliability Value

No platform-level single point of failure

Each system is independently highly available: a single system fault is isolated and does not spread to other modules.

Platform Base Support

Level 1 · IntelliOne unified platform layer

Every system runs on the IntelliOne platform base, so platform-level redundancy supports all five systems and their shared modules uniformly. Dual-node hot-standby cluster, multi-copy data storage and dual communication links remove platform-level single points of failure, keeping the global management view continuously available.

Deployment-Level Redundancy

Level 3 · Engineering delivery standard

Hardware-Level Redundancy

All control hardware, gateways and core servers use industrial dual-power redundant configuration, so a single supply failure does not affect device operation.

Network-Level Redundancy

Dual physical network links are deployed, with management and control networks physically separated and each carrying its own redundant paths.

Power-Level Redundancy

Critical control nodes include UPS backup as standard, so monitoring, emergency control and data reporting continue during a power loss.

Standard delivery configuration on every project — not an optional add-on. No single point of failure on site, suited to complex grid and environmental conditions across Southeast Asia.

See DCIM in the Live Console

Explore monitoring, alarms and optimization flows with real-time console access.